﻿<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hardware - Rubytech</title>
	<atom:link href="https://www.rubytech.com.tw/rubytech/faq_cat/hardware/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.rubytech.com.tw/rubytech</link>
	<description>Professional ODM Partner to Customize Networking products</description>
	<lastBuildDate>Thu, 28 Jan 2016 10:35:08 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.rubytech.com.tw/rubytech/wp-content/uploads/2017/11/logo.png</url>
	<title>Hardware - Rubytech</title>
	<link>https://www.rubytech.com.tw/rubytech</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Which UTP pairs are used for delivers power on ECO layer2 PoE managed series switches and web PoE series switches ?</title>
		<link>https://www.rubytech.com.tw/rubytech/faq/which-utp-pairs-are-used-for-delivers-power-on-eco-layer2-poe-managed-series-switches-and-web-poe-series-switches/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=which-utp-pairs-are-used-for-delivers-power-on-eco-layer2-poe-managed-series-switches-and-web-poe-series-switches</link>
		
		<dc:creator><![CDATA[rubyadmin]]></dc:creator>
		<pubDate>Thu, 28 Jan 2016 10:35:08 +0000</pubDate>
				<guid isPermaLink="false">/rubytech/?post_type=faq&#038;p=4191</guid>

					<description><![CDATA[<p>pins 1 and 2 (pair #2 inT568B ) and pins 3 and 6 (pair #3 in T568B)</p>
<p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/which-utp-pairs-are-used-for-delivers-power-on-eco-layer2-poe-managed-series-switches-and-web-poe-series-switches/">Which UTP pairs are used for delivers power on ECO layer2 PoE managed series switches and web PoE series switches ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>pins 1 and 2 (pair #2 in<a href="http://en.wikipedia.org/wiki/T568B">T568B</a> ) and pins 3 and 6 (pair #3 in T568B)</p><p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/which-utp-pairs-are-used-for-delivers-power-on-eco-layer2-poe-managed-series-switches-and-web-poe-series-switches/">Which UTP pairs are used for delivers power on ECO layer2 PoE managed series switches and web PoE series switches ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>What kinds of UTP category agree with use on the switch ?</title>
		<link>https://www.rubytech.com.tw/rubytech/faq/what-kinds-of-utp-category-agree-with-use-on-the-switch/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=what-kinds-of-utp-category-agree-with-use-on-the-switch</link>
		
		<dc:creator><![CDATA[rubyadmin]]></dc:creator>
		<pubDate>Thu, 28 Jan 2016 10:32:30 +0000</pubDate>
				<guid isPermaLink="false">/rubytech/?post_type=faq&#038;p=4188</guid>

					<description><![CDATA[<p>Category 5.category 5e .category 6</p>
<p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/what-kinds-of-utp-category-agree-with-use-on-the-switch/">What kinds of UTP category agree with use on the switch ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Category 5.category 5e .category 6</p><p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/what-kinds-of-utp-category-agree-with-use-on-the-switch/">What kinds of UTP category agree with use on the switch ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to do factory default on ECO layer2 managed series switches and web series switches ?</title>
		<link>https://www.rubytech.com.tw/rubytech/faq/how-to-do-factory-default-on-eco-layer2-managed-series-switches-and-web-series-switches/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=how-to-do-factory-default-on-eco-layer2-managed-series-switches-and-web-series-switches</link>
		
		<dc:creator><![CDATA[rubyadmin]]></dc:creator>
		<pubDate>Thu, 28 Jan 2016 10:31:53 +0000</pubDate>
				<guid isPermaLink="false">/rubytech/?post_type=faq&#038;p=4185</guid>

					<description><![CDATA[<p>Stab /Push reset button until the front LED all flash, then release the button.</p>
<p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/how-to-do-factory-default-on-eco-layer2-managed-series-switches-and-web-series-switches/">How to do factory default on ECO layer2 managed series switches and web series switches ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Stab /Push reset button until the front LED all flash, then release the button.</p><p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/how-to-do-factory-default-on-eco-layer2-managed-series-switches-and-web-series-switches/">How to do factory default on ECO layer2 managed series switches and web series switches ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>What’s baud rate on the switch ?</title>
		<link>https://www.rubytech.com.tw/rubytech/faq/whats-baud-rate-on-the-switch/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=whats-baud-rate-on-the-switch</link>
		
		<dc:creator><![CDATA[rubyadmin]]></dc:creator>
		<pubDate>Thu, 28 Jan 2016 10:25:04 +0000</pubDate>
				<guid isPermaLink="false">/rubytech/?post_type=faq&#038;p=4163</guid>

					<description><![CDATA[<p>Baud rate : 115200 Data : 8bit Parity : none Stop : 1 but Flow control : none</p>
<p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/whats-baud-rate-on-the-switch/">What’s baud rate on the switch ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Baud rate : 115200</p>
<p>Data : 8bit</p>
<p>Parity : none</p>
<p>Stop : 1 but</p>
<p>Flow control : none</p><p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/whats-baud-rate-on-the-switch/">What’s baud rate on the switch ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How do I check the switch’s MAC table on web UI?</title>
		<link>https://www.rubytech.com.tw/rubytech/faq/how-do-i-check-the-switchs-mac-table-on-web-ui/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=how-do-i-check-the-switchs-mac-table-on-web-ui</link>
		
		<dc:creator><![CDATA[rubyadmin]]></dc:creator>
		<pubDate>Thu, 28 Jan 2016 10:06:03 +0000</pubDate>
				<guid isPermaLink="false">/rubytech/?post_type=faq&#038;p=4154</guid>

					<description><![CDATA[<p>You can check it on web UI as the following path. Configuration &#8212;&#62; Filtering Data Base And CLI command as below: Switch# fdb Switch (fdb)# show mac-table No    Type     MAC Address        VID   Ports &#8212;-  &#8212;&#8212;-  &#8212;&#8212;&#8212;&#8212;&#8212;&#8211;  &#8212;-  &#8212;&#8212;&#8212;&#8212;&#8212; 1     Dynamic  00-1a-80-4a-b8-e7  1     6 2     Static   00-40-c7-aa-bb-cc  1     None,CPU 3     Static   33-33-00-00-00-01  1     1-26,CPU 4     Static   [&#8230;]</p>
<p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/how-do-i-check-the-switchs-mac-table-on-web-ui/">How do I check the switch’s MAC table on web UI?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>You can check it on web UI as the following path.</p>
<p>Configuration &#8212;&gt; Filtering Data Base</p>
<p>And CLI command as below:</p>
<p>Switch# fdb</p>
<p>Switch (fdb)# show mac-table</p>
<p>No    Type     MAC Address        VID   Ports</p>
<p>&#8212;-  &#8212;&#8212;-  &#8212;&#8212;&#8212;&#8212;&#8212;&#8211;  &#8212;-  &#8212;&#8212;&#8212;&#8212;&#8212;</p>
<p>1     Dynamic  00-1a-80-4a-b8-e7  1     6</p>
<p>2     Static   00-40-c7-aa-bb-cc  1     None,CPU</p>
<p>3     Static   33-33-00-00-00-01  1     1-26,CPU</p>
<p>4     Static   33-33-00-00-00-02  1     1-26,CPU</p>
<p>5     Static   33-33-ff-17-38-fa  1     1-26,CPU</p>
<p>6     Static   33-33-ff-aa-bb-cc  1     1-26,CPU</p>
<p>Switch (fdb)# show static-mac</p>
<p>Total static MAC address : 0</p><p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/how-do-i-check-the-switchs-mac-table-on-web-ui/">How do I check the switch’s MAC table on web UI?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to warm boot via CLI ?</title>
		<link>https://www.rubytech.com.tw/rubytech/faq/how-to-warm-boot-via-cli/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=how-to-warm-boot-via-cli</link>
		
		<dc:creator><![CDATA[rubyadmin]]></dc:creator>
		<pubDate>Thu, 28 Jan 2016 09:52:18 +0000</pubDate>
				<guid isPermaLink="false">/rubytech/?post_type=faq&#038;p=4124</guid>

					<description><![CDATA[<p>Execute this command “reboot“ Switch# reboot</p>
<p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/how-to-warm-boot-via-cli/">How to warm boot via CLI ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Execute this command “reboot“</p>
<p>Switch# reboot</p><p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/how-to-warm-boot-via-cli/">How to warm boot via CLI ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>What kinds of managed interface does this switch support ?</title>
		<link>https://www.rubytech.com.tw/rubytech/faq/curabitur-eget-leo-at-velit-imperdiet-viaculis-vitaes-2/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=curabitur-eget-leo-at-velit-imperdiet-viaculis-vitaes-2</link>
		
		<dc:creator><![CDATA[rubyadmin]]></dc:creator>
		<pubDate>Wed, 14 Jan 2015 01:00:16 +0000</pubDate>
				<guid isPermaLink="false">http://sw-themes.com/porto_dummy/?post_type=faq&#038;p=159</guid>

					<description><![CDATA[<p>CLI Web UI Telnet SNMP</p>
<p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/curabitur-eget-leo-at-velit-imperdiet-viaculis-vitaes-2/">What kinds of managed interface does this switch support ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>CLI</p>
<p>Web UI</p>
<p>Telnet</p>
<p>SNMP</p><p>The post <a href="https://www.rubytech.com.tw/rubytech/faq/curabitur-eget-leo-at-velit-imperdiet-viaculis-vitaes-2/">What kinds of managed interface does this switch support ?</a> first appeared on <a href="https://www.rubytech.com.tw/rubytech">Rubytech</a>.</p>]]></content:encoded>
					
		
		