Product Overview
IPGS-2706U industrial L2+ managed GbE UPoE switch is the next generation industrial grade Ethernet switch offering powerful L2 and basic L3 features with better functionality and usability. In addition to the extensive management features, IPGS-2706U also provides carrier Ethernet features such as OAM/CFM/ERPS/EPS/PTPv2, of which make them suitable for industrial and carrier Ethernet applications.
IPGS-2706U delivers 4 (10M/100M/1G) RJ45 with 4 UPoE (Support 802.3 at/af/UPoE, and total up to 240W) ports, 2 GbE SFP ports and RJ45 console port. IPGS-2706U provides high HW performance and environment flexibility for industrial and carrier Ethernet applications.
The embedded Device Managed System (DMS) features provides users with the benefits of easy-to-use/configure/install/troubleshoot in the video surveillance, wireless access, and other industrial applications. IPGS-2706U is ideal to deliver management simplicity, better user experience, and lowest total cost of ownership.
| Key Features | Customer Benefits |
|---|---|
| Comprehensive L2 Support | Provided comprehensive L2 switching capabilities with easy-to-use management to move your data smoother and faster |
| arrier Ethernet Support | Provided the ideal combination of afford-ability and capabilities for Carrier networking (1588v2, OAM, CFM, ELPS) |
| Ethernet Ring Protocol Switching (ITU G.8032) | Provided link redundancy ability to reduce networking service risks and guarantee network service availability |
| Rapid Ring | Rapid ring is able quickly to recover network-segment failures; if a link in a network fails, Rapid ring will instantaneously activate the blocked path to continue forwarding the data-all in a recovery time of less than 20 ms |
| Dual DC Power Input | Power failover when power supplies are connected to different circuits reducing network operating risk |
IPGS-2706U industrial L2+ managed GbE UPoE switch is the next generation industrial grade Ethernet switch offering powerful L2 and basic L3 features with better functionality and usability. In addition to the extensive management features, IPGS-2706U also provides carrier Ethernet features such as OAM/CFM/ERPS/EPS/PTPv2, of which make them suitable for industrial and carrier Ethernet applications.
IPGS-2706U delivers 4 (10M/100M/1G) RJ45 with 4 UPoE (Support 802.3 at/af/UPoE, and total up to 240W) ports, 2 GbE SFP ports and RJ45 console port. IPGS-2706U provides high HW performance and environment flexibility for industrial and carrier Ethernet applications.
The embedded Device Managed System (DMS) features provides users with the benefits of easy-to-use/configure/install/troubleshoot in the video surveillance, wireless access, and other industrial applications. IPGS-2706U is ideal to deliver management simplicity, better user experience, and lowest total cost of ownership.
Key Features
- Rapid Ring (R-Ring)
- Built in Device Management System (DMS)
- iPush APP for real time alarm notification
- ITU-T G.8031 Ethernet Linear Protection Switching (EPS)
- ITU-T G.8032 Ethernet Ring Protection Switching (ERPS)
- IEEE 1588v2 PTP
- IEEE 802.3ah OAM
- IEEE 802.1ag CFM (ITU-T Y.1731 Performance monitoring)
- DHCP Server
- IEEE 802.3az Energy Efficient Ethernet standard for green Ethernet application
- IIEEE 802.3af/at Power over Ethernet
- IPv4/IPv6 L3 static route
- EtherNet/IP (by request)
- PROFINET (by request)
Benefits
The switch deliver extensive industrial and carrier grade functionalities, including R-Ring, ITU-T G.8031, ITU-T G.8032, IEEE 1588v2 PTP, OAM, CFM, etc. It also have enhanced L2/L3 features for better manageability and usability.
IPGS-2706 provides advanced PoE features such as PoE auto-checking, PoE scheduling, and PoE power delay for users to manage the powered devices more easily. With extensive PoE+ mode configured, IPGS-2706 can even provides power with up to 38W per port.
It offers users with better price/performance ratio in industrial application, and provide secure and reliable functionalities for metro/carrier Ethernet deployments.
[/accordionitem]
[accordionitem]
The switch performs IEEE1588v2 PTP, including transparent and boundary clock capabilities, implementations in hardware, so there is no performance penalty on packet processing.
The hardware architecture ensures low latency and high time accuracy – which is critical for delay-sensitive financial and mobile applications.
[/accordionitem]
[accordionitem]
Service assurance is provided through a rich feature set of operations, administration, and maintenance (OAM) functionalities. It can simplify and facilitate the management of Carrier network, resulting in diminishing operational costs.
The Ethernet access device also offers standards-based fault and performance management in adherence with 1731 PM and 802.1ag connectivity fault management (CFM) standards.
These features contribute to significant reduction in operational expenditures and allows for troubleshooting without expensive truck rolls.
[/accordionitem]
[accordionitem]
The DMS provides embedded functions to facilitate devices management at anytime and anywhere. Its user-friendly interface helps users to manage devices intuitively.
It supports various IP device types (e.g. PC, IP-phone, IP-camera, WiFi-AP) for end users to enhance manageability and save time/cost during installation/maintenance stages.
[/accordionitem]
[accordionitem]
The switch is designed to help companies to save power needs and reduce TCO by Energy Efficient Ethernet (IEEE 802.3az). It can be used for customers to build a green Ethernet networking environment.
[/accordionitem][/cq_vc_accordion]
Specifications
Port Configuration
| Total Ports | RJ45 (10M/100M/1G) | Uplinks (100M/1G) | Console | Ring Mgmt. | DI/DO |
|---|---|---|---|---|---|
| 6 | 4 | 2 SFP | RJ45 | DIP | 1/1 |
Hardware Performance
| Forwarding Capacity (Mpps) | Switching Capacity (Gbps) | Mac Table (K) | Jumbo Frames (Bytes) |
|---|---|---|---|
| 8.928 | 12 | 8 | 9216 |
Environmental Range
| Operating Temperature | Storage Temperature | Operating Humidity | Altitude | |||
|---|---|---|---|---|---|---|
| Fahrenheit | Centigrade | Fahrenheit | Centigrade | Feet | Meters | |
| -40 to 167 | -40 to 75 | -40 to 185 | -40 to 85 | 5% to 95% non-condensing | <10000 | <3000 |
Dimension, Weights, Mounting
| Dimension (WxHxD) | Weight | Mounting Type | |||
|---|---|---|---|---|---|
| Millimeter | Inches | Kilograms | Pounds | ||
| 62x 135x 130 | 2.4x 5.3x 5.1 | < 1 | <2.2 | DIN rail | |
Voltage and Frequency
| Primary Power Supply – DC Input Voltage | |
|---|---|
| DC Nominal | 12/24/48 VDC dual inputs |
| PoE SKUs | 9.6 to 57 VDC |
| DC Operating Range |
|
PoE Power Capacity
| Available PoE Power | Number of Ports That Support PoE(15.4W), PoE+(30.0W), or UPoE(60W) |
|---|---|
| 120W | Each of port 1 – 4 support PoE/ PoE+ within available PoE Power ( per port 38W by request ) |
Certification
| Regulatory Compliance | |
|---|---|
| EMS | EN61000-4-2 ESD, EN61000-4-3 RS, EN61000-4-4 EFT, EN61000-4-5 Surge, EN61000-4-6 CS, EN61000-4-8 PFMF, (EN61000-6-2 by request) |
| EMI | FCC Part 15 Class A (EN61000-3-2, EN61000-3-3, EN61000-6-4, EN55022, EN55011 by request) |
| Safety | CE, (EN60950 by request) |
| Mechanical Stability | |
| Vibration | IEC 60068-2-6 |
| Shock | IEC 60068-2-27 |
| Freefall | IEC 60068-2-32 |
| Approvals (by request) | |
| Railway Norm | EN50121-4, EN50155 |
| Transportation | NEMA TS2 |
| Substation | IEC61850-3, IEEE1613 |
| Marine | DNV |
Software Features
| Ring Management | |
|---|---|
| ITU-T G.8031 | Supports ITU-T G.8031 Ethernet Linear Protection Switching |
| ITU-T G.8032 | Supports ITU-T G.8032 Ethernet Ring Protection Switching |
| Rapid Ring | Enable self-recover time in less than 20ms |
| Device Management System (DMS) | |
| Graphical Monitoring |
|
| Find my Switch | Search and manage your real switches quickly. |
| Traffic Monitoring | Display visual chart of network traffic of all devices and monitor every port at any time from switches |
| Trouble Shooting |
|
| Industrial Protocols (by Request) | |
| EtherNet/IP | EtherNet/IP is an industrial Ethernet network that combines standard Ethernet technologies with the media-independent Common Industrial Protocol. |
| PROFINET | It can be recorded and displayed using an Ethernet analysis tool such as Wireshark. The topology can be shown using analysis tools such as TH Scope. |
| Ethernet OAM | |
| IEEE 802.3ah OAM | Supports Operations, Administration & Management |
| IEEE 802.1ag & ITU-T Y.1731 Flow OAM |
|
| Layer 2 Switching | |
| Spanning Tree Protocol (STP) |
|
| Trunking |
|
| VLAN |
|
| DHCP Relay |
|
| IGMP v1/v2/v3 Snooping | IGMP limits bandwidth-intensive multicast traffic to only the requesters. Supports 1024 multicast groups |
| IGMP Querier | IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router |
| IGMP Proxy | IGMP snooping with proxy reporting or report suppression actively filters IGMP packets in order to reduce load on the multicast router |
| MLD v1/v2 Snooping | Delivers IPv6 multicast packets only to the required receivers |
| Multicast VLAN Registration (MVR) | Delivers IPv6 multicast packets only to the required receivers |
| Layer 3 Switching | |
| IPv4 Static Routing | IPv4 Unicast: Static routing |
| IPv6 Static Routing | IPv6 Unicast: Static routing |
| Security | |
| Secure Shell (SSH) | SSH secures Telnet traffic in or out of the switch, SSH v1 and v2 are supported |
| Secure Sockets Layer (SSL) | SSL encrypts the http traffic, allowing advanced secure access to the browser-based management GUI in the switch |
| IEEE 802.1X |
|
| Layer 2 Isolation Private VLAN Edge | PVE (also known as protected ports) provides L2 isolation between clients in the same VLAN. Supports multiple uplinks |
| Port Security | Locks MAC addresses to ports, and limits the number of learned MAC address |
| IP Source Guard | Prevents illegal IP address from accessing to specific port in the switch |
| RADIUS/ TACACS+ | Supports RADIUS and TACACS+ authentication. Switch as a client |
| Storm Control | Prevents traffic on a LAN from being disrupted by a broadcast, multicast, or unicast storm on a port |
| DHCP Snooping | A feature acts as a firewall between untrusted hosts and trusted DHCP servers |
| ACLs | Supports up to 256 entries. Drop or rate limitation based on:
|
| Loop Protection | To prevent unknown unicast, broadcast and multicast loops in Layer 2 switching configurations. |
| Quality of Service | |
| Hardware Queue | Supports 8 hardware queues |
| Scheduling |
|
| Classification |
|
| Rate Limiting |
|
| Management | |
| Dying Gasp | Support Dying Gasp notification on loss of Power |
| HW Monitoring | Temperature Detection and Alarm |
| HW Watchdog | Supported to resume operation from CPU hang up |
| IEEE 1588v2 PTP | Support IEEE 1588 v2 PTP (Precision Time Protocol) |
| iPush |
|
| DHCP Server | Support DHCP server to assign IP to DHCP clients |
| Remote Monitoring (RMON) | Embedded RMON agent supports RMON groups 1,2,3,9 (history, statistics, alarms, and events) for enhanced traffic management, monitoring and analysis |
| Port Mirroring | Traffic on a port can be mirrored to another port for analysis with a network analyzer or RMON probe. Up to N-1 (N is Switch’s Ports) ports can be mirrored to single destination port. A single session is supported. |
| UPnP | The Universal Plug and Play Forum, an industry group of companies working to enable device-to-device interoperability by promoting Universal Plug and Play |
| s-Flow | The industry standard for monitoring high speed switched networks. It gives complete visibility into the use of networks enabling performance optimization, accounting/billing for usage, and defense against security threats |
| IEEE 802.1ab (LLDP) |
|
| Web GUI Interface | Built-in switch configuration utility for browser-based device configuration |
| CLI | For users to configure/manage switches in command line modes |
| Dual Image | Independent primary and secondary images for backup while upgrading |
| SNMP | SNMP version1, 2c and 3 with support for traps, and SNMP version 3 user-based security model (USM) |
| Firmware Upgrade |
|
| NTP | Network Time Protocol (NTP) is a networking protocol for clock synchronization between computer systems over packet-switched |
| Other Management |
|
| Power over Ethernet (PoE) | |
| Port Configuration | Supports per port PoE configuration function |
| PoE Scheduling | Supports per port PoE scheduling to turn on/off the PoE devices (PDs) |
| Auto-checking | Check the link status of PDs. Reboot PDs if there is no responses |
| Power Delay | The switch provides power to the PDs based on delay time when PoE switch boots up, in order to protect switch from misuse of the PDs |
There is no Product Series Datasheet for this model.