1. U can enable STP/RSTP/MSTP (this is an example for setting RSTP on port 2~8 ) :

Switch(stp)# version rstp

Switch(stp)# p-mode 2-8 enable

Switch(stp)# sh pconf

 

Port  Mode      AdminEdge AutoEdge  restrRole restrTcn  bpduGuard Point2point

—-  ——–  ——————  ——————  ———————

Aggr  Disabled  Disabled  Enabled   Disabled  Disabled  Disabled  Enabled

 

Port  Mode      AdminEdge AutoEdge  restrRole restrTcn  bpduGuard Point2point

—-  ——–  ——————  ——————  ———————

1     Disabled  Disabled  Enabled   Disabled  Disabled  Disabled  Auto

2     Enabled   Disabled  Enabled   Disabled  Disabled  Disabled  Auto

3     Enabled   Disabled  Enabled   Disabled  Disabled  Disabled  Auto

4     Enabled   Disabled  Enabled   Disabled  Disabled  Disabled  Auto

5     Enabled   Disabled  Enabled   Disabled  Disabled  Disabled  Auto

6     Enabled   Disabled  Enabled   Disabled  Disabled  Disabled  Auto

7     Enabled   Disabled  Enabled   Disabled  Disabled  Disabled  Auto

8     Enabled   Disabled  Enabled   Disabled  Disabled  Disabled  Auto

9     Disabled  Disabled  Enabled   Disabled  Disabled  Disabled  Auto

10    Disabled  Disabled  Enabled   Disabled  Disabled  Disabled  Auto

Switch(stp)#

 

 

 

 

  1. U can enable loop-protect (this is an example for enable loop-protect )

Switch# loop-protect

Switch(loop-protect)# mode enable

Switch(loop-protect)# show config

Loop Protection   : Enabled

Transmission Time : 5

Shutdown Time     : 180

 

Port  Mode      Action            Transmit

—-  ——–  —————-  ——–

1     Enabled   Shutdown          Enabled

2     Enabled   Shutdown          Enabled

3     Enabled   Shutdown          Enabled

4     Enabled   Shutdown          Enabled

5     Enabled   Shutdown          Enabled

6     Enabled   Shutdown          Enabled

7     Enabled   Shutdown          Enabled

8     Enabled   Shutdown          Enabled

9     Enabled   Shutdown          Enabled

10    Enabled   Shutdown          Enabled

 

Note :

  1. Do not enable STP/RSTP/MSTP and loop-protect on the same port .
  2. Do not enable loop-protect on bone port (it meaning not directly connect to user )